Mike Chaney's Tech Corner

Mike's Software => Qimage Ultimate => Topic started by: admin on December 17, 2016, 04:08:47 PM



Title: v2017.113 issues/comments
Post by: admin on December 17, 2016, 04:08:47 PM
http://www.ddisoftware.com/qimage-u

v2017.113   Dec 17, 2016

Priority: Low

v2017.113 offers expanded options for media size sorting (under Edit/Preferences) and the reset function (Settings tab) as well as some bug fixes.

Mike


Title: Re: v2017.113 issues/comments
Post by: Ernst Dinkla on December 21, 2016, 02:05:40 PM
Hello Mike,

Running into an odd error with 113. Windows 7. Installing 112 again does not give that error, tried the 113 install 2 times.

When I load a job from the log with recall it shows the thumbnail(s) in the recall window but does not load the image on the print page. Error that sticks is:
"The system can not find the file specified"  The file address is correct and nothing has changed since the old job was done. Files are on an E named harddisc. As written 112 does it correctly.

Met vriendelijke groet, Ernst

http://www.pigment-print.com/spectralplots/spectrumviz_1.htm
November 2016 update, 700+ inkjet media white spectral plots


Title: Re: v2017.113 issues/comments
Post by: admin on December 22, 2016, 01:16:21 AM
114 (due out Thursday) should fix that.  Thanks for the report.

Mike


Title: Re: v2017.113 issues/comments
Post by: Ernst Dinkla on December 23, 2016, 03:52:03 PM
114 (due out Thursday) should fix that.  Thanks for the report.

Mike

Thank you Mike.

I have installed 114. I guess it is solved but I might have a special problem anyway. In the recall window of 112, 113 and 114, the first 1, 2 or 3 logged jobs show images from different jobs. It is after those jobs say number 4 that the job images are shown and loaded correctly. The last start and finish job do not show images at all and the finish job is always a Print to File one, while that was not the way I left QU.

When I open one of those first jobs not all are loaded and an error appears:
"Scan line index out of range" or "Division by zero"

I guess my log file is too long meanwhile or corrupted but deleting several jobs there does not solve it.


Met vriendelijke groet, Ernst

http://www.pigment-print.com/spectralplots/spectrumviz_1.htm
November 2016 update, 700+ inkjet media white spectral plots